Three Dimensional Magnetic Equivalent Circuit Analysis of the Modified Homopolar Linear Synchronous Machine
ID:281 Submission ID:281 View Protection:PUBLIC Updated Time:2021-06-18 18:15:43 Hits:941 Poster Presentation

Start Time:2021-07-02 14:21 (Asia/Shanghai)

Duration:1min

Session:[SP] Poster Session » [P1] Poster Session 1 & 2

No files

Abstract
In this paper, a three dimensional magnetic equivalent circuit (3D-MEC) model is proposed for the modified homopolar linear synchronous machine (H-LSM), which analyzes the air gap flux density, flux linkage, back EMF and electromagnetic forces. By adopting the 3D-MEC method, the computing time for H-LSM is largely reduced with considerable computation accuracy at the same time, which is verified by the three dimensional finite element model (3D-FEM). Therefore, the preliminary design progress can be speeded up via the 3D-MEC model.
Keywords
Homopolar linear synchronous machine (H-LSM), three dimensional magnetic equivalent circuit method (3D-EMC), machine analysis.
Speaker
Wei Xu
Huazhong University of Science and Technology

Submission Author
Wei Xu Huazhong University of Science and Technology
Comment submit