Calculation of primary end windings electromagnetic force of multiphase linear induction motors
ID:119 Submission ID:119 View Protection:ATTENDEE Updated Time:2021-06-30 17:44:12 Hits:928 Oral Presentation

Start Time:2021-07-02 10:30 (Asia/Shanghai)

Duration:20min

Session:[S3] Concurrent Session 3 » [S3-1] Oral Session 3 & 6

Presentation File

Tips: The file permissions under this presentation are only for participants. You have not logged in yet and cannot view it temporarily.

Abstract
The primary current of the multiphase linear induction motor(LIM) reaches tens of thousands of amperes in short-time pulse operation. The motor end windings are subject to a large amount of alternating electromagnetic force. Accurate calculation of the alternating electromagnetic force is the theoretical basis for the fixed design of the end windings. Taking the end structure of twelve-phase LIM as the research object, based on Biot-Savart law, this paper calculates the magnetic density and electromagnetic force density in different directions of each end winding segments in a pole distance and analyzes the fluctuation law of end electromagnetic force, to provide a reference for the end windings structure of the motor. This method has the advantages of high computing speed and flexible application.
Keywords
Multiphase linear induction motor, end windings, electromagnetic force density, magnetic density
Speaker
Yichao Zhang
Naval University of Engineering

Submission Author
Zhengqing Han Naval University of Engineering
Comment submit
Verification code Change another
All comments