Unified Phase-domain Model of Dual-three Phase Segmented Powered PMLSM considering different Connection Types and Fault Conditions
ID:275 Submission ID:275 View Protection:PUBLIC Updated Time:2021-06-26 18:01:53 Hits:844 Poster Presentation

Start Time:2021-07-02 16:29 (Asia/Shanghai)

Duration:1min

Session:[SP] Poster Session » [P3] Poster Session 5 & 6

Abstract
In this paper, a phase-domain segmented powered permanent magnet linear synchronous machine (SPPMLSM) model considering different connection types and fault conditions is presented and investigated. Firstly, the current constraints under health condition, one or two phase open-circuit fault working conditions with single and double neutral points are summarized. Then a matrix D corresponding to the different working conditions is adopted to acquire a unified SP-PMLSM phase-domain model. Secondly, the back-EMF is precisely modeled based on Sigmoid function to take the effect during the mover passing through the segment into account. Finally, the effectiveness of unified phase-domain model is built in a FPGA and validated by a real-time simulation test set.
Keywords
Phase-domain model, PMLSM, Segmented powered, Open phase fault
Speaker
Liming Shi
Institute of Electrical Engineering of the Chinese Academy of Sciences

Keyu Guo
Institute of Electrical Engineering, Chinese Academy of Sciences

Submission Author
Liming Shi Institute of Electrical Engineering of the Chinese Academy of Sciences
Comment submit
Verification code Change another
All comments